Usage of methods diffuse Mueller-matrix introscopy for early diagnosis of endometriosis based on study of dehydrated films of peritoneal fluid

Authors

DOI:

https://doi.org/10.32782/2077-6594/2024.4/15

Keywords:

early diagnosis, infertility, endometriosis, diffuse endoscopy, peritoneal fluid

Abstract

The aim of the study. To evaluate the effectiveness of early diagnosis of endometriosis using the methods of diffuse Mullermatrix endoscopy of scattering dehydrated films of peritoneal fluid. Material and methods. Two groups of samples were studied: peritoneal fluid obtained during diagnostic laparoscopy – control group 3.1 – 68 samples; peritoneal fluid obtained during diagnostic laparoscopy in women with endometriosis associated with infertility – experimental group 3.2 – 59 samples. Results. Detected the presence of fluctuations in the amount of circular birefringence of the supramolecular polycrystalline chiral structure of leukocytes in the peritoneal fluid films of patients from all groups; increase in the magnitude of fluctuations of circular birefringence of supramolecular structures of peritoneal fluid samples of patients with endometriosis; the correlation of changes in the optically active (chiral) structure of supramolecular networks of leukocytes in the peritoneal fluid and the growth of circular birefringence fluctuations in endometriosis; diagnostic and statistically reliable markers of the pathological process and the effectiveness of the treatment of endometriosis - the values of the average and dispersion, which characterize the distribution of the fluctuations of the circular birefringence. pi=1;2;3;4  0,05 Conclusions. By means of statistical analysis of a series of thesiograms of coordinate distributions of random values of fluctuations in the amount of variations in the optical anisotropy of biological preparations, additional markers for early diagnosis of endometriosis were experimentally established. Linear birefringence – good (88.1% – 89.7%) diagnostic accuracy - groups 3.1–3.2; circular birefringence – excellent (96.8% – 97.4%) and very good (92.9% – 93.7%) diagnostic accuracy – groups 3.1–3.2; linear dichroism – very good (90.5% – 92.1%) diagnostic accuracy – groups 3.1–3.2; circular dichroism – very good (89.8% – 92.1%) diagnostic accuracy – groups 3.1–3.2. SM SM SM SM SM SM SM SM SM SM SM SM SM SM 1 1 1 2 3 4 1 2 3 4 1 2 3 4

References

Trifonyuk L, Sdobnov A, Baranowski W, Ushenko V, Olar O, Dubolazov A, et al. Differential Mueller matrix imaging of partially depolarizing optically anisotropic biological tissues. Lasers Med Sci. 2020;35(4):877-91. doi: 10.1007/s10103-019-02878-2.

Ushenko VA, Sdobnov AY, Mishalov WD, Dubolazov AV, Olar OV, Bachinskyi VT, et al. Biomedical applications of Jonesmatrix tomography to polycrystalline films of biological fluids. Journal of Innovative Optical Health Sciences [Internet]. 2019[cited 2024 Aug 03];12(6):1950017. Available from: https://www.worldscientific.com/doi/epdf/10.1142/S1793545819500172 doi: 10.1142/S1793545819500172.

Ushenko VA, Hogan BT, Dubolazov A, Grechina AV, Boronikhina TV, Gorsky M, et al. Embossed topographic depolarisation maps of biological tissues with different morphological structures. Sci Rep [Internet]. 2021[cited 2024 Aug 03];11(1):3871. Available from: https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7886906/pdf/41598_2021_Article_83017.pdf doi: 10.1038/s41598-021-83017-2.

Peyvasteh M, Dubolazov A, Popov A, Ushenko A, Ushenko Y, Meglinski I. Two-point Stokes vector diagnostic approach for characterization of optically anisotropic biological tissues. J Phys D: Appl Phys [Internet]. 2020[cited 2024 Sep 07];53(39):395401. Available from: https://iopscience.iop.org/article/10.1088/1361-6463/ab9571/pdf doi: 10.1088/1361-6463/ab9571.

Dubolazov A, Ushenko V, Litvinenko O, Bachinskiy V, Petrushak A, Karachevtsev A, et al. Polarization-interference mapping of the distributions of the parameters of the Stokes vector of the object field of a biological optically anisotropic layer. Proceedings of SPIE - The International Society for Optical Engineering. 2020;11369:113691N. doi: 10.1117/12.2553953.

Published

2024-12-30

Issue

Section

Science - health care practice