The Effects of Distance and Warming Temperature on Intensity of Extremely Low Frequency Electromagnetic Field from Forced-Air Warming System
DOI:
https://doi.org/10.32782/2077-6594/2026.3/21Keywords:
extremely low frequency electromagnetic field, operating room, air warmerAbstract
Purpose. Electronic devices, increasingly used in operating rooms, heavily depend on mains electricity. This may significantly increase occupational exposure to extremely low frequency electromagnetic field. As a possible carcinogen as per International Agency for Research on Cancer, Swedish Confederation of Professional Employee recommended it should be below 2 mG. Forced air warming system is used to prevent hypothermia. This study was to investigate the effect of distance and warming temperature on extremely low frequency electromagnetic field intensity from Bair-Hugger™ Warming Unit, in order to find the minimum safe distance from the device. Materials and methods. The forced-air warming unit was hung on the side of an operating table in an empty operating room, with all other electronic devices turned off. With three different warming temperatures, electromagnetic field was measured at 15, 30, and 45 cm from the anterior surface of the device. Data was collected at a sampling time of 0.5 times per second for 10 minutes. Kruskal-Wallis one-way analysis was used. Results. Increasing warming temperature and reducing the distance from the device resulted in a significant increase in electromagnetic field intensity (p <0.05). At 45 cm in particular, low and medium warming temperatures showed significantly lower intensity compared to high temperature (p<0.05). Exposure below 2.0 mG was achieved only when it was at 45 cm regardless of temperature. Conclusions. Health workers should be aware of occupational exposure to extremely low frequency electromagnetic field and avoid as much as possible. It is suggested to stay at least 45 cm away from 3M Bair Hugger™ Warming Unit.
References
Gajšek P, Ravazzani P, Grellier J, Samaras T, Bakos J, Thuróczy G. Review of studies concerning electromagnetic field (EMF) exposure assessment in Europe: Low frequency fields (50 Hz–100 kHz). International journal of environmental research and public health. 2016;13(9):875. DOI:10.3390/ijerph13090875
Wertheimer N, Leeper E. Electrical wiring configurations and childhood cancer. Am J Epidemiol. 1979;109(3):273-84.
Ahlbom A, Day N, Feychting M, Roman E, Skinner J, Dockerty J, et al. A pooled analysis of magnetic fields and childhood leukaemia. Br J Cancer. 2000;83(5):692-8. DOI: 10.1054/bjoc.2000.1376
Greenland S, Sheppard AR, Kaune WT, Poole C, Kelsh MA. A pooled analysis of magnetic fields, wire codes, and childhood leukemia. Epidemiology. 2000:624-34. DOI: 10.1097/00001648-200011000-00003
International Agency for Research on Cancer. Working Group on the Evaluation of Carcinogenic Risks to Humans. Nonionizing radiation, Part 1: static and extremely low-frequency (ELF) electric and magnetic fields. IARC Monogr Eval Carcinog Risks Hum. 2002;80:1-395.
Lai H. Genetic Effects of Non-Ionizing Electromagnetic Fields Bioinitiative 2012: A Rationale for a Biologically based Public Exposure Standard for Electromagnetic Fields (ELF and RF).
Zhou H, Chen G, Chen C, Yu Y, Xu Z. Association between extremely low-frequency electromagnetic fields occupations and amyotrophic lateral sclerosis: a meta-analysis. PLoS One. 2012;7(11):e48354. DOI: 10.1371/journal.pone.0048354
Sage C DC. The BioInitiative Report 2012: a rationale for a biologically-based public exposure standard for electromagneticfields (ELF and RF). 2012.
Lee JH, Lee HC, Kim HD, Kim JY, Kim DW, Nam YT, et al. How much are anesthesiologists exposed to electromagnetic fields in operating rooms? Yonsei Med J. 2003;44(1):133-7. DOI: 10.3349/ymj.2003.44.1.133
TCO Development AB. TCO Certified Generation 8. . 2019.
Jung JW, Kim YH, Go GC, Park JH, Jeon SY, Lee SE, et al. Diurnal variation of extremely low frequency electromagnetic field in an empty operating room. Anaesthesia, Pain & Intensive Care. 2013;17(1):59-62.
Roh JH, Kim DW, Lee SJ, Kim JY, Na SW, Choi SH, et al. Intensity of extremely low-frequency electromagnetic fields produced in operating rooms during surgery at the standing position of anesthesiologists. Anesthesiology: The Journal of the American Society of Anesthesiologists. 2009;111(2):275-8. DOI: 10.1097/ALN.0b013e3181a9188b
Sessler DI. Mild perioperative hypothermia. N Engl J Med. 1997;336(24):1730-7.
Simpao AF, Feldman JM, Cohen DE. Smith’s Anesthesia for Infants and Children (Ninth Edition), 16. In: ; 2017. p. 298-327.
Cho KR, Kim MH, Ko MJ, Jung JW, Lee KH, Park YH, et al. Extremely Low Frequency Electromagnetic Field from Convective Air Warming System on Temperature Selection and Distance. Iran J Public Health. 2014 Dec;43(12):1635-9.
Tenmars. TM-192_TM-192D 3-axis EMF Meter: application, specification.
Haynal A, Regli F. Zusammenhang der amyotrophischen Lateralsklerose mit gehäuften Elektrotraumata. Stereotact Funct Neurosurg. 1964;24(3-4):189-98.
Shin E, Jeong JH, Kim HJ, Jang C, Yamada K, Nabeshima T, et al. Exposure to extremely low frequency magnetic fields enhances locomotor activity via activation of dopamine D1-like receptors in mice. Journal of pharmacological sciences. 2007;105(4):367-71. doi: 10.5607/en.2011.20.3.130
Shin E, Nguyen XT, Nguyen TL, Pham D, Kim H. Exposure to extremely low frequency magnetic fields induces fos-related antigen-immunoreactivity via activation of dopaminergic D1 receptor. Experimental neurobiology. 2011;20(3):130-6. DOI: 10.1254/jphs.sc0070348
Dasdag S, Ketani M, Akdag Z, Ersay A, Sari I, Demirtas Ö, et al. Whole-body microwave exposure emitted by cellular phones and testicular function of rats. Urol Res. 1999;27(3):219-23. DOI: 10.1007/s002400050113
Yan J, Agresti M, Bruce T, Yan YH, Granlund A, Matloub HS. Effects of cellular phone emissions on sperm motility in rats. Fertil Steril. 2007;88(4):957-64. DOI: 10.1016/j.fertnstert.2006.12.022
Huss A, Küchenhoff J, Bircher A, Heller P, Kuster H, Niederer M, et al. Symptoms attributed to the environment–a systematic, interdisciplinary assessment. Int J Hyg Environ Health. 2004;207(3):245-54. DOI: 10.1078/1438-4639-00286
Röösli M, Moser M, Baldinini Y, Meier M, Braun-Fahrländer C. Symptoms of ill health ascribed to electromagnetic field exposure–a questionnaire survey. Int J Hyg Environ Health. 2004;207(2):141-50. DOI: 10.1078/1438-4639-00269
Hagström M, Auranen J, Ekman R. Electromagnetic hypersensitive Finns: symptoms, perceived sources and treatments, a questionnaire study. Pathophysiology. 2013;20(2):117-22. DOI: 10.1016/j.pathophys.2013.02.001
Sessler DI, Schroeder M, Merrifield B, Matsukawa T, Cheng C. Optimal duration and temperature of prewarming. Anesthesiology: The Journal of the American Society of Anesthesiologists. 1995;82(3):674-81. DOI: 10.1097/00000542-199503000-00009
Matsukawa T, Sessler DI, Sessler AM, Schroeder M, Ozaki M, Kurz A, et al. Heat flow and distribution during induction of general anesthesia. Anesthesiology: The Journal of the American Society of Anesthesiologists. 1995;82(3):662-73. DOI: 10.1097/00000542-199503000-00008